N3K-C3164Q-2PK Specification |
|||
|
Physical
|
•2 RU fixed form-factor switch •64 QSFP+ ports; each supports native 40 Gigabit Ethernet and 4 x 10 Gigabit Ethernet modes •2 redundant power supplies •3+1 redundant fans •Management, console, and USB flash-memory ports |
||
|
Performance
|
•5.12 Tbps switching capacity •Forwarding rate up to 3.8 bpps •Line-rate traffic throughput (both Layer 2 and 3) on all ports •Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames) |
||
|
Hardware tables and scalability |
|||
|
Number of VLANS |
MSTP: 4096 |
||
|
Number of spanning-tree instances |
MSTP: 64 RPVST+: 507 |
||
|
Number of access control list (ACL) entries |
4000 to 16000 ingress 1000 to 4000 egress |
||
|
Routing table |
Maximum number of longest prefix match (LPM) routes 128,000 Maximum number of IP host entries 120,000 Maximum number of MAC address entries 96,000 |
||
|
Number of EtherChannels |
256 |
||
|
Number of ports per EtherChannel |
32 |
||
|
Buffer size |
48 MB shared |
||
|
System memory |
16 GB |
||
|
Number of spanning-tree instances |
MSTP: 64 RPVST+: 507 |
||
|
Hardware tables and scalability |
|||
|
Number of spanning-tree instances |
MSTP: 64 RPVST+: 507 |
||
|
Number of access control list (ACL) entries |
4000 to 16000 ingress 1000 to 4000 egress |
||
|
Routing table |
Maximum number of longest prefix match (LPM) routes 128,000 Maximum number of IP host entries 120,000 Maximum number of MAC address entries 96,000 |
||
|
Number of EtherChannels |
256 |
||
|
Number of ports per EtherChannel |
32 |
||
|
Buffer size |
48 MB shared |
||
|
System memory |
16 GB |
||
|
Power |
|||
|
Frequency |
50 to 60 Hz |
||
|
Power supply types |
AC |
||
|
Typical operating power |
803 Watts (W) with SR4 optics at 100% load; 2 PSUs |
||
|
Maximum power |
1100 Watts (W) |
||
|
AC PSUs •Input voltage •Frequency •Efficiency |
•200 to 240 VAC •50 to 60 Hz •93% at 220V |
||
|
Typical heat dissipation |
2739 BTU/hr (with SR4 optics at 100% load) |
||
|
Maximum heat dissipation |
3753 BTU/hr |
||
|
Cooling |
Port-side intake and port-side exhaust options Port-side intake: Yes Port-side exhaust: Post FCS |
||
|
Dimensions (height x width x depth) |
3.48 x 17.41 x 22.32in. (88.4 x 442 x 566 mm) |
||
|
Environment |
|||
|
Operating temperature |
32 to 104°F (0 to 40°C) |
||
|
Storage temperature |
-40 to 158°F (-40 to 70°C) |
||
|
Operating relative humidity |
•10 to 85% noncondensing •Up to 5 days at maximum (85%) humidity Recommend ASHRAE data center environment |
||
|
Storage relative humidity |
5% to 95% noncondensing |
||
|
Altitude |
0 to 10,000 ft (0 to 3000m) |
||
|
Software Features |
|||
|
Maximum number of longest prefix match (LPM) routes |
128,000 |
||
|
Maximum number of IP host entries |
120,000 |
||
|
Maximum number of MAC address entries |
96,000 |
||
|
Number of multicast routes |
16,000, up to 60,000 |
||
|
Number of Interior Gateway Management Protocol (IGMP) snooping groups |
8,000, up to 60,000 |
||
|
Number of access control list (ACL) entries |
1000 to 4000 egress 4000 to 16000 ingress |
||
|
Maximum number of VLANs |
4000 |
||
|
Maximum number of Virtual Routing and Forwarding (VRF) instances |
1000 |
||
|
Maximum number of links in a PortChannel |
32 |
||
|
Maximum number of ECMP paths |
64 |
||
|
Maximum number of PortChannels |
256 |
||
|
Number of active Switched Port Analyzer (SPAN) sessions |
4 |
||
|
Maximum number of Rapid per-VLAN Spanning Tree (RPVST) instances |
507 |
||
|
Maximum number of Hot Standby Router Protocol (HSRP) groups |
490 |
||
|
Maximum number of Multiple Spanning Tree (MST) instances |
64 |
||
|
Maximum number of tunnel endpoints (VTEP) and VXLAN physical servers (per VLAN) |
10,000 |
||
|
Regulatory Standards Compliance: Safety and EMC |
|||
|
Regulatory compliance |
•Products should comply with CE Markings per directives 2004/108/EC and 2006/95/EC |
||
|
Safety |
•UL 60950-1 Second Edition •CAN/CSA-C22.2 No. 60950-1 Second Edition •EN 60950-1 Second Edition •IEC 60950-1 Second Edition •AS/NZS 60950-1 •GB4943 |
||
|
EMC: Emissions |
•47CFR Part 15 (CFR 47) Class A •AS/NZS CISPR22 Class A •CISPR22 Class A •EN55022 Class A •ICES003 Class A •VCCI Class A •EN61000-3-2 •EN61000-3-3 •KN22 Class A •CNS13438 Class A |
||
|
EMC: Immunity |
•EN55024 •CISPR24 •EN300386 •KN24 |
||
The bundle typically includes rack-mounting kits, power cables, and console cables necessary for initial setup.
Compared to similar products, the N3K-C3164Q-2PK offers high port density, excellent performance, and scalability suited for modern data center demands.
The N3K-C3164Q-2PK falls under Default Category/Switches/Cisco Switches/Cisco Nexus 3000 Series and Default Category/Switches/Data Center Switches/Cisco Nexus 3000 Switches.
We promise that our products are original and genuine only. Brand-new products will be brand new and sealed to ensure no malfunctions, and second-hand products will undergo strict testing before shipment.
We offer a 1-year warranty for brand-new products and a 90-day warranty for second-hand products. During the warranty period, if the equipment you purchase has any operational defects, we will replace it for you (the warranty does not cover faults caused by human damage and improper use).
Once the product malfunctions, please notify us as soon as possible, and we will appreciate your detailed description or photos.
The warranty period is calculated from the date of receipt of the goods. For any issues or inquiries regarding your purchase, please feel free to contact us via WhatsApp (+86 152 7186 6615) or Skype/Email: sales@infdevice.com